CODING INFORMATION - GATE, GLOBE, CHECK VALVE

This ordering code, used in conjuncture with the Standard Materials Available Chart shown at right, allow you to code any standard Smith Gate, or Check Valve, or a number of common variations. Code letter have been assigned for your selection.

The first three or four figures always indicates the basic valve style. These figures can be taken directly from the preceding pages.

The second group of five letter indicates the options available.  If a standard valve is required, as from the listing below, enter the code letters in sequence as indicated by the colors, and be certain to enter "0" for any standard selection.

The third group of three numbers indicates the normal pipe size in 1/100ths.

You will find special orders coded with a Z plus four numbers in the options section, for the sake of records and nameplate marking.  Special options include body drains, handwheel extensions, material in different combinations, etc.  For such non-coded items, contact your Smith representative.
 

TYPICAL VALVE CODING
Forged carbon steel, OS&Y Gate Valve 316 S.S. trim,
237 & 1625GF packing, 316 S.S. & GRF gasket, socket weld ends - 1" size

0 8 0 0
-
O S O G W
-
1 0 0
VALVE STYLE   OPTIONS   PIPE SIZE

Insert 3 or 4 diget Smith number (888, 1578, G80, etc.) as shown on previous pages.
Prefix with "0" for 3 giget Fig. No.

Indicate the options you wish from the listings below, making references to the Standard Materials Available shown on top of page at right.
Be certain to enter "0" in proper space for any standard selection.

CODE CODE
1/4 NPS/8 DN - 025
3/8 NPS/10 DN 037
1/2 NPS/15 DN 050
3/4 NPS/20 DN 075
1 NPS/25 DN 100
1-1/4 NPS/32 DN 125
1-1/2 NPS/40 DN 150
2 NPS/50 DN 200
3 NPS/80 DN 300
Use "X" in place of last size digit for oxygen clean valve.